<p align="center" style="text-align:center"><b style="mso-bidi-font-weight: normal"><span style="font-size:9.0pt;font-family:Arial;color:navy">YÖNETMELİK</span></b></p> <p style="text-indent:28.3pt;line-height:12.0pt;mso-line-height-rule: exactly" class="1-Baslk"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">Enerji Piyasası Düzenleme Kurumundan:</span></p> <p style="line-height:12.0pt;mso-line-height-rule:exactly" class="2-OrtaBaslk"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">ELEKTRİK PİYASASI ŞEBEKE YÖNETMELİĞİNDE DEĞİŞİKLİK</span></p> <p style="line-height:12.0pt;mso-line-height-rule:exactly" class="2-OrtaBaslk"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">YAPILMASINA İLİŞKİN YÖNETMELİK</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">MADDE 1 –</span></b><span style="font-size:9.0pt; mso-hansi-font-family:"Times New Roman""> <span class="GramE">22/1/2003</span> tarihli ve 25001 sayılı Resmî Gazete’de yayımlanan Elektrik Piyasası Şebeke Yönetmeliğinin EK 18’i aşağıdaki şekilde değiştirilmiştir.</span></p> <p style="line-height:12.0pt;mso-line-height-rule:exactly" class="2-OrtaBaslk"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">“EK 18</span></p> <p style="line-height:12.0pt;mso-line-height-rule:exactly" class="2-OrtaBaslk"><span class="GramE"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">RÜZGAR</span></span><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman""> ENERJİSİNE DAYALI ÜRETİM TESİSLERİNİN ŞEBEKE BAĞLANTI KRİTERLERİ</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">E.<span class="GramE">18.1</span> KAPSAM</span></b></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Bu kriterler, iletim sistemine bağlı <span class="GramE">rüzgar</span> enerjisine dayalı üretim tesisleri ile kurulu gücü 10 MW ve üzerinde olan dağıtım sistemine bağlı rüzgar enerjisine dayalı üretim tesislerine uygulanır. Bu ekte yer almayan konular için bu Yönetmeliğin ilgili hükümleri geçerlidir.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">E.<span class="GramE">18.2</span> RÜZGAR ENERJİSİNE DAYALI ÜRETİM TESİSLERİNİN ARIZA SONRASI SİSTEME KATKISI</span></b></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">İletim veya dağıtım sistemi bağlantı noktasındaki şebeke faz-faz geriliminin Şekil E.18.2.1’de verilen 1 numaralı ve 2 numaralı bölgelerde kaldığı süre boyunca, herhangi bir fazda veya tüm fazlarda oluşan gerilim düşümlerinde <span class="GramE">rüzgar</span> türbinleri şebekeye bağlı kalmalıdır.</span></p> <p style="line-height:12.0pt;mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman""> </span></p> <p align="center" style="text-align:center" class="3-NormalYaz"><span style="mso-no-proof:yes"><img width="637" height="317" alt="Şekil E" src="http://www.resmigazete.gov.tr/eskiler/2013/01/20130103-10_dosyalar/image002.gif" /></span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman""> </span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Arıza sırasında gerilim düşümünün 1 numaralı bölgede kaldığı durumlarda, rüzgar türbini aktif gücü, arıza temizlendikten hemen sonra saniyede <span class="GramE">nominal</span> gücünün en az %20’si oranında artırılarak, üretilebilecek maksimum aktif güç değerine ulaşmalıdır.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Arıza sırasında gerilim düşümünün 2 numaralı bölgede kaldığı durumlarda ise, rüzgar türbini aktif gücü, arıza temizlendikten hemen sonra saniyede <span class="GramE">nominal</span> gücünün en az %5’i oranında artırılarak, üretilebilecek maksimum aktif güç değerine ulaşmalıdır.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Şebeke bağlantı noktasında meydana gelen ± %10’a kadar olan gerilim dalgalanmaları (0,9pu – 1,1pu) normal işletme koşulları olup, rüzgar enerjisine dayalı üretim tesisleri E.<span class="GramE">18.6</span> Reaktif Güç Desteği maddesinde belirtilen esaslara uymalıdır.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Şebeke bağlantı noktasında ifade edilen arıza durumlarında oluşacak ± %10’dan büyük gerilim dalgalanmalarında her bir rüzgar türbin <span class="SpellE">generatörü</span> tasarlanmış geçici rejim anma değerlerini aşmadan, gerekirse <span class="GramE">nominal</span> akımın %100’üne varacak seviyelerde, <span class="SpellE">endüktif</span> veya <span class="SpellE">kapasitif</span> yönde maksimum reaktif akım desteği sağlamalıdır. Bu geçici rejim maksimum reaktif akım destek değerine %10 hata payı ile 60ms içerisinde ulaşmalı ve 1,5 saniye boyunca sürdürülebilmelidir.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">E.<span class="GramE">18.3</span> AKTİF GÜÇ KONTROLÜ</span></b></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">İletim sistemine bağlı <span class="GramE">rüzgar</span> enerjisine dayalı üretim tesislerinde Yönetmeliğin 61 inci maddesinde tanımlanan acil durumlarda aktif güç kontrolü yapılabilecektir. <span class="GramE">Rüzgar</span> enerjisine dayalı üretim tesisinin aktif güç çıkışı, gerektiğinde TEİAŞ tarafından gönderilecek sinyallerle, santralin o anki şartlarda <span class="SpellE">emreamade</span> gücünün %20-%100’ü arasında otomatik olarak kontrol edilebilir olmalıdır. Bu kapsamda;</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">a) Kurulu gücü 100 MW ve altında olan <span class="GramE">rüzgar</span> enerjisine dayalı üretim tesisleri için, yük alma hızı dakikada santral kurulu gücünün %5’ini geçmemelidir, yük atma hızı ise dakikada santral kurulu gücünün %5’inden az olmamalıdır.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">b) Kurulu gücü 100 <span class="SpellE">MW’ın</span> üzerinde olan <span class="GramE">rüzgar</span> enerjisine dayalı üretim tesisleri için, yük alma hızı dakikada santral kurulu gücünün %4’ünü geçmemelidir, yük atma hızı ise dakikada santral kurulu gücünün %4’ünden az olmamalıdır.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">E.<span class="GramE">18.4</span> FREKANS TEPKİSİ</span></b></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span class="GramE"><span style="font-size: 9.0pt;mso-hansi-font-family:"Times New Roman"">Rüzgar</span></span><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman""> türbinleri bu Yönetmeliğin 11’inci maddesinde belirtilen frekans aralıkları ve çalışma sürelerini sağlamalıdır.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Bu çalışma şartlarına ilave olarak, ilgili üretim tesisinde şebeke frekansının 50,2 <span class="SpellE">Hz’in</span> üzerinde olduğu durumlarda ilave <span class="GramE">rüzgar</span> türbini devreye girmemelidir.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span class="GramE"><span style="font-size: 9.0pt;mso-hansi-font-family:"Times New Roman"">Rüzgar</span></span><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman""> türbini frekans tepkisi Şekil E.18.4.1’de verilen güç-frekans eğrisi sınırları içinde kalacak şekilde olmalıdır.</span></p> <p style="line-height:12.0pt;mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman""> </span></p> <p align="center" style="text-align:center;tab-stops:1.0cm" class="MsoNormal"><span style="mso-no-proof:yes"><img width="636" height="323" src="http://www.resmigazete.gov.tr/eskiler/2013/01/20130103-10_dosyalar/image004.gif" alt="" /></span></p> <p align="center" style="text-align:center;line-height: 12.0pt;mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-family:Times;mso-ascii-font-family:"Times New Roman"; mso-bidi-font-family:"Times New Roman";mso-fareast-language:KO">Ş</span></b><b style="mso-bidi-font-weight:normal"><span style="mso-fareast-language:KO">ekil E.18.4.1 </span></b><b style="mso-bidi-font-weight:normal"><span style="font-family:Times;mso-ascii-font-family:"Times New Roman"; mso-bidi-font-family:"Times New Roman";mso-fareast-language:KO">–</span></b><b style="mso-bidi-font-weight:normal"><span style="mso-fareast-language:KO"> </span></b><span class="GramE"><span style="mso-fareast-language:KO">R</span><span style="font-family:Times;mso-ascii-font-family:"Times New Roman"; mso-bidi-font-family:"Times New Roman";mso-fareast-language:KO">ü</span><span style="mso-fareast-language:KO">zgar</span></span><span style="mso-fareast-language: KO"> T</span><span style="font-family:Times;mso-ascii-font-family:"Times New Roman"; mso-bidi-font-family:"Times New Roman";mso-fareast-language:KO">ü</span><span style="mso-fareast-language:KO">rbini G</span><span style="font-family: Times;mso-ascii-font-family:"Times New Roman";mso-bidi-font-family:"Times New Roman"; mso-fareast-language:KO">üç</span><span style="mso-fareast-language:KO">-Frekans E</span><span style="font-family:Times;mso-ascii-font-family:"Times New Roman"; mso-bidi-font-family:"Times New Roman";mso-fareast-language:KO">ğ</span><span style="mso-fareast-language:KO">risi</span></p> <p align="center" style="text-align:center;line-height: 12.0pt;mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt; mso-hansi-font-family:"Times New Roman""> </span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span class="GramE"><span style="font-size: 9.0pt;mso-hansi-font-family:"Times New Roman"">Rüzgar</span></span><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman""> türbini, şebeke frekansı 47,5-50,3 Hz aralığında olduğu sürece <span class="SpellE">emreamade</span> gücünün tamamını üretebilecek özellikte olmalıdır. Şebeke frekansının 50,3 <span class="SpellE">Hz’in</span> üzerine çıkması durumunda <span class="GramE">rüzgar</span> santralleri, Şekil E.18.4.1’de verilen aktif güç-frekans karakteristiklerini takip ederek %4 hız düşümü değerini sağlayacak şekilde yük atmalı ve 51,5 <span class="SpellE">Hz’de</span> ise tamamıyla devre dışı olmalıdır.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">E.<span class="GramE">18.5</span> REAKTİF GÜÇ KAPASİTESİ</span></b></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Rüzgar enerjisine dayalı üretim tesisi, iletim veya dağıtım sistemi bağlantı noktasında, Şekil E.18.5.1’de koyu çizgilerle belirtilen sınırlar <span class="GramE">dahilindeki</span> reaktif güç değerleri için her noktada sürekli olarak çalışabilir olmalıdır.</span></p> <p style="text-align:justify;tab-stops:1.0cm" class="MsoNormal"><span style="mso-fareast-language:KO"> </span></p> <p align="center" style="text-align:center;tab-stops:1.0cm" class="MsoNormal"><span style="mso-ignore:vglayout;position:relative;z-index:1"><span style="left:0px;position:absolute;left:179px;top:-1px;width:311px; height:26px"><img width="311" height="26" src="http://www.resmigazete.gov.tr/eskiler/2013/01/20130103-10_dosyalar/image005.gif" alt="" /></span></span><span style="mso-no-proof:yes"><img width="615" height="314" src="http://www.resmigazete.gov.tr/eskiler/2013/01/20130103-10_dosyalar/image007.jpg" alt="" /></span></p> <p align="center" style="text-align:center;tab-stops:1.0cm" class="MsoNormal"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt; mso-fareast-language:KO">Şekil E.18.5.1</span></b><span style="font-size: 9.0pt;mso-fareast-language:KO"> – <span class="GramE">Rüzgar</span> Santrali Reaktif Güç Kapasite Eğrisi</span></p> <p align="center" style="text-align:center;line-height: 12.0pt;mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt; mso-hansi-font-family:"Times New Roman""> </span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Belirlenen ve yan hizmet anlaşmaları ile kayıt altına alınan bu zorunlu reaktif güç değerlerine Şekil E.18.5.2’de belirtildiği gibi gerilime bağlı olarak gerektiğinde ulaşılabilmelidir.</span></p> <p style="margin-bottom:6.0pt;text-align:justify; tab-stops:1.0cm" class="MsoNormal"><span style="mso-fareast-language:KO"> </span></p> <p align="center" style="text-align:center;tab-stops:1.0cm" class="MsoNormal"><span style="mso-no-proof:yes"><img width="541" height="402" alt="Untitled3" src="http://www.resmigazete.gov.tr/eskiler/2013/01/20130103-10_dosyalar/image009.gif" /></span></p> <p align="center" style="text-align:center;tab-stops:1.0cm" class="MsoNormal"><span style="mso-fareast-language:KO"> </span></p> <p align="center" style="text-align:center;tab-stops:1.0cm" class="MsoNormal"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt; mso-fareast-language:KO">Şekil E.18.5.2 </span></b><span style="font-size: 9.0pt;mso-fareast-language:KO">Zorunlu Reaktif Güç Değerlerinin Bağlantı Noktası Gerilimine Bağlı Değişimi</span></p> <p align="center" style="text-align:center;line-height: 12.0pt;mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt; mso-hansi-font-family:"Times New Roman""> </span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">E.<span class="GramE">18.6</span> REAKTİF GÜÇ DESTEĞİ SAĞLANMASI</span></b></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span class="GramE"><span style="font-size: 9.0pt;mso-hansi-font-family:"Times New Roman"">Rüzgar</span></span><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman""> enerjisine dayalı üretim tesisleri, bağlantı noktası geriliminin 0,9pu ve 1,1pu değerleri arasında tanımlanan normal işletme koşullarında, bağlantı noktası geriliminin denge durumu değişimlerine, Şekil E.18.6.1’de belirlenmiş karakteristikler doğrultusunda sürekli olarak cevap vermelidir.</span></p> <p style="text-align:justify;text-indent:1.0cm" class="MsoNormal"><span style="mso-fareast-language:KO"> </span></p> <p style="text-align:justify" class="MsoNormal"><span style="mso-no-proof: yes"><img width="604" height="377" alt="Untitled2b" src="http://www.resmigazete.gov.tr/eskiler/2013/01/20130103-10_dosyalar/image011.gif" /></span></p> <p align="center" style="text-align:center;text-indent:24.05pt" class="MsoNormal"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt; mso-fareast-language:KO">Şekil E.18.6.1</span></b><span style="font-size: 9.0pt;mso-fareast-language:KO"> – <span class="GramE">Rüzgara</span> Dayalı Üretim Tesisleri Tarafından Sisteme Verilecek Reaktif Güç Desteği Eğrisi</span></p> <p align="center" style="text-align:center;line-height: 12.0pt;mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt; mso-hansi-font-family:"Times New Roman""> </span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Gerilim set değeri TEİAŞ tarafından şebeke bağlantı noktası gerilimi için verilecektir. <span class="GramE">Rüzgar</span> enerjisine dayalı üretim tesisleri şebeke bağlantı noktası gerilimindeki değişikliklere Şekil E.18.6.1’de görüldüğü gibi oransal tepki vermelidir.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Şekil E.18.6.1’deki grafikte “<span class="SpellE">droop</span>” değeri, %2-%7 arasında bir değer olup TEİAŞ tarafından belirlenecektir. (“<span class="SpellE">Droop</span>” (gerilim düşümü) değeri, üretim tesisinin reaktif çıkış gücünü 0’dan aşırı ikazlı maksimum reaktif güç değerine veya 0’dan düşük ikazlı maksimum reaktif çıkış güç değerine çıkması için şebeke geriliminde verilen gerilim set değerine göre oluşacak % gerilim değişimidir.)</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">İlgili üretim tesisi, şebeke bağlantı noktası geriliminde, normal işletme koşullarında gerçekleşebilecek ani bir basamak değişimine, en geç 200ms’de cevap vermeye başlamalı,<span style="mso-spacerun:yes"> </span>reaktif çıkış gücü olması gereken denge değerinin %90’ına en geç 1 saniye içerisinde ulaşmalı ve en geç 2 saniye içerisinde dengeye oturmalıdır. Denge durumunda, reaktif çıkış gücünde oluşabilecek <span class="SpellE">salınımların</span> tepe değeri gerçekleşen değişimin %2’sini geçmemelidir.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">E.<span class="GramE">18.7</span> RÜZGAR ENERJİSİNE DAYALI ÜRETİM TESİSİ ŞEBEKE BAĞLANTI TRAFOSU</span></b></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">İletim sistemine doğrudan bağlı <span class="GramE">rüzgar</span> enerjisine dayalı üretim tesislerinin şebeke bağlantı trafoları yük altında otomatik kademe değiştirme özelliğine sahip olmalıdır. Trafoların sahip olması gerekli diğer özellikleri bu Yönetmelik ve Elektrik İletim Sistemi Arz Güvenilirliği ve Kalitesi Yönetmeliği’nde tanımlanmaktadır.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">E.<span class="GramE">18.8</span> RÜZGAR ENERJİSİNE DAYALI ÜRETİM TESİSLERİNCE TEİAŞ’A SAĞLANACAK BİLGİLER</span></b></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span class="GramE"><span style="font-size: 9.0pt;mso-hansi-font-family:"Times New Roman"">Rüzgar</span></span><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman""> enerjisine dayalı üretim tesisi için <span class="SpellE">TEİAŞ’a</span> yapılan bağlantı anlaşması aşamasında aşağıdaki bilgiler <span class="SpellE">TEİAŞ’a</span> sunulur:</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">1. <span class="GramE">Rüzgar</span> enerjisine dayalı üretim tesisinin <span class="SpellE">MWe</span> olarak toplam kurulu güç kapasitesi.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">2. Rüzgar türbinlerinin sayısı ve her bir rüzgar türbininin <span class="SpellE">MWe</span> cinsinden <span class="GramE">nominal</span> gücü ve tipi (asenkron, senkron, tip 3, tip 4, vs.).</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">3. Türbinlerin şebekeye bağlantı şekli (doğrudan bağlı; çift <span class="SpellE">uyartımlı</span> asenkron jeneratör, AC/DC/AC <span class="SpellE">çeviricilisenkron</span> jeneratör).</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">4. <span class="GramE">Rüzgar</span> türbinlerinin minimum ve maksimum rüzgar hızı değerlerindeki işletim durumu (rüzgar hızına göre rüzgar türbinlerindeki üretim değişimini gösteren grafikler).</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">5. Gerilim ve akım <span class="SpellE">harmonikleri</span> ile <span class="SpellE">fliker</span> etkisini sınırlandırmak üzere kurulacak sistemlerin tipi ve etiket değerleri.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">6. ISO/IEC 17025 akreditasyonuna sahip bir kuruluş tarafından, IEC 61400-12 standardı normlarına göre yapılmış ölçümlere dayalı olarak, IEC 61400-21 standardına uygun olarak hazırlanmış güç kalitesi etki değerlendirme raporu.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">7. Sistem etütlerinde kullanılmak üzere tesis edilecek olan <span class="GramE">rüzgar</span> türbinlerinin statik ve dinamik modelleri. Bu kapsamda, türbinlerin statik ve dinamik verilerine ilaveten, <span class="GramE">rüzgar</span> çiftliğindeki kablo sisteminin de statik veri detayları (gerilim seviyesi, kesit, uzunluk, vs).</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">8. <span class="GramE">Rüzgar</span> çiftliklerinin <span class="SpellE">master</span> kontrolcü fonksiyonel şemaları ve matematiksel modelleri ile set edilen parametreleri.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">9. Bölgesel 1/25.000’lik coğrafik harita üzerinde tesis edilecek <span class="GramE">rüzgar</span> enerjisine dayalı üretim tesisi ve rüzgar türbinlerinin yerinin coğrafi koordinatları.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">10. TEİAŞ tarafından ihtiyaç duyulabilecek diğer veriler.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Elektrik Piyasası Yan Hizmetler Yönetmeliği hükümleri uyarınca, ilgili yan hizmete katılımı zorunlu olan yeni bir üretim tesisinin ticari işletmeye geçebilmesi için, tesisler adına kayıtlı tüzel kişi, Bu Yönetmeliğin 8 inci maddesinin dördüncü fıkrası gereği, TEİAŞ ile ilgili yan hizmet anlaşmasının imzalanması ya da söz konusu üretim tesisinin üretim faaliyeti gösteren ilgili tüzel kişi tarafından daha önce imzalanmış olan ilgili yan hizmetler anlaşması kapsamına <span class="GramE">dahil</span> edilmesine müteakiben, sağlayacakları yan hizmetlerin “kayıt, izleme ve kontrolü” ve rüzgar tahmin ve izleme sistemi için, tanımlanacak parametre ve değişkenleri belirlenen veri formatı ve veri iletim süreci dahilinde <span class="SpellE">TEİAŞ’a</span> sunmalıdır.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">E.<span class="GramE">18.9</span> RÜZGAR ENERJİSİ SANTRALLERİNİN İZLENMESİ</span></b></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">Lisanslı olan tüm <span class="GramE">rüzgar</span> enerjisi santralleri, merkezi Yenilenebilir Enerji Genel Müdürlüğünde olan Rüzgar Gücü İzleme ve Tahmin Merkezinden (RİTM) ve dolayısıyla TEİAŞ Yük Tevzi Merkezlerinden izlenmesini sağlamak üzere gerekli altyapıyı kurar. Teknik donanımların taşıyacağı özellikler <span class="GramE">Yenilenebilir</span> Enerji Genel Müdürlüğü internet sayfasında yayımlanır.”</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">MADDE 2 –</span></b><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman""> Aynı Yönetmeliğin geçici 10 uncu maddesine aşağıdaki şekilde ikinci fıkra eklenmiştir.</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><span style="font-size:9.0pt;mso-hansi-font-family: "Times New Roman"">“(2) Ek 18’in değiştirilen maddelerinin yürürlük tarihinden önce bağlantı anlaşması imzalamış olan rüzgar enerjisine dayalı üretim tesisleri için <span class="GramE">24/9/2008</span> tarihli Ek 18 uygulanmaya devam edilir.”</span></p> <p style="text-indent:28.3pt;line-height:12.0pt; mso-line-height-rule:exactly" class="3-NormalYaz"><b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">MADDE 3 –</span></b><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman""> Bu Yönetmelik yayımı tarihinde yürürlüğe girer.</span></p> <b style="mso-bidi-font-weight:normal"><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman"">MADDE 4 –</span></b><span style="font-size:9.0pt;mso-hansi-font-family:"Times New Roman""> Bu Yönetmelik hükümlerini Başkan yürütür.</span><br />